QRE

HomeProductsPower TransformerAuto Power Transformer220kV Three-phase Three-winding Auto Transformer with OCTC

220kV Three-phase Three-winding Auto Transformer with OCTC

Payment Type:
L/C,T/T
Incoterm:
FOB,CFR,CIF
Min. Order:
1 Set/Sets
Transportation:
Ocean
Port:
China Sea Port
Share:
  • Product Description
Overview
Product Attributes

Model No.220kV Auto Transformer

BrandQRE- QIANCHAO

ApplicationPower

PhaseThree

CoilCore-type Transformer

Cooling MethodOil-immersed Type Transformer

CertificationISO9001-2000

UsagePower Transformer

Frequency CharacteristicsPower Frequency

Supply Ability & Additional Information

PackagingSeaworthy Packing

Productivity300 sets/year

TransportationOcean

Place of OriginChina

Supply AbilityHigh

CertificateISO

HS Code85042311

PortChina Sea Port

Payment TypeL/C,T/T

IncotermFOB,CFR,CIF

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Seaworthy Packing


Part I: Product Overview for 220kV Auto Transformer


220kV high quality oil immersed Auto transformer has optimized design using advanced technologies, in order to offer low noise, low partial discharge, high short circuit withstand capability. Advanced design software are used for electromagnetic calculation and design of transformer, while 3-D, 2-D CAD software for structural design ensure sufficient safety margin during short circuit period. This is based on in-depth theoretical and experimental studies on magnetic, thermal, mechanical strength and short circuit strength. To ensure reliability of the transformer, the insulation is decided based on calculation on main and vertical insulation. The accurate calculation of the electric field distribution in inner coils will ensure voltage gradient and at coil end it will ensure lower partial discharge.

Part II: Product Features

1.   Potential distribution is effectively improved by application of software to calculate the impact and gradient potential distribution. The potential calculation is also done between various parts of the coil including between the coil and coil and earthing.

 1

2.   Low loss: Magnetic flux leakage calculation and corresponding measures to effectively reduce the stray loss, and in the meantime effectively prevent local overheating and lower temperature rise of winding hot spots. The electromagnetic optimizing design software is applied to optimize the core and winding design.

2 

3.   High resistance to short-circuit capacity: Apply transformer resistance to short-circuit capacity accounting software to design HV winding and LV winding. HV winding will be designed as central outlet, up and down parallel connection with axial oil path; the regulating winding will be designed as central outlet in the middle of HV winding with up and down parallel connection to improve transformer short-circuit resistance.

3 

4.   Low partial discharge, extend Transformer Service life.

(1) Analyze calculation of electric field to improve the electric field concentrated region.

(2) The way of vacuum oil filling will effectively prevent the formation of air bubbles inside the transformer and insulation parts to reduce partial discharge.

4 

5.   Low noise: Lower the noise level by choosing high quality steel core material; right flux density and the self-vibration frequency of the core; application of high resistance to short-circuit of the body structure; and improving the connection method of tank and active part.

6.   Low temperature rise: Apply reasonable oil flow distribution structure by calculation of oil flow distribution; reduce the winding hot spot temperature rise and the average temperature rise in order to increase overload capacity of each part, extend the life of transformer.


Part III: Product Main Parameter

Model

Rated Voltage (kV)

Vector Group

Step-up

Step-down

Short-circuit Impedance (%)

H.V

M.V

L.V

No load loss

(kW)

Load loss (kW)

No-load current

(%)

No load loss

(kW)

Load loss (kW)

No-load current

(%)

Step-up

Step-down

OSS -31500/220

220±2x2.5%

 

230±2x2.5%

 

242±2x2.5%

115

121

6.6

10.5

21

36

37

38.5

YNa0d11

20.0

111

0.45

17.0

94.0

0.40

HV-MV

12~14

 

HV-LV

8~12

 

MV-LV

14~18

HV-MV

8~10

 

HV-LV

28~34

 

MV-LV

18~24

OSS -40000/220

23.0

136

0.45

20.0

114

0.40

OSS -50000/220

27.0

161

0.40

24.0

136

0.34

OSS -63000/220

32.0

190

0.40

28.0

162

0.34

OSS -90000/220

40.0

262

0.34

36.0

222

0.28

OSS -120000/220

10.5

13.8

15.75

18

21

36

37

38.5

49.0

323

0.34

44.0

273

0.28

OSS -150000/220

58.0

384

0.28

52.0

324

0.26

OSS -180000/220

67.0

439

0.28

60.0

367

0.26

OSS -240000/220

79.0

545

0.26

71.0

478

0.20



 
Part IV: Outline Drawing

 220kV





Product Categories : Power Transformer > Auto Power Transformer

Email to this supplier
  • *Subject:
  • *To:
    Mr. James
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
HomeProductsPower TransformerAuto Power Transformer220kV Three-phase Three-winding Auto Transformer with OCTC
Send Inquiry
*
*

James

Mr. James

SEND INQUIRY

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send